VMM Host performance counters report 0 Cpu and Memory

Goedemorgen! as the Dutch say,

Often Virtual Machine Manager Hyper-V hosts will report 0% CPU and 0KB Memory, I have seen this issue for VMM 2012, 2012 SP1, and 2012 R2.

A restart will often fix the issue but its often easier to restart the virtual machine manager agent.

If an agent restart doesn’t fix the issue then you can try the steps documented by Kristian Nese here: http://kristiannese.blogspot.nl/2012/12/vmm-doesnt-show-hosts-performance.html

Be aware that when the performance counters are not working then this could potentially have an affect on things like Dynamic Optimization (VMM) or other 3rd party resource optimization tools (such as VMTurbo) – this is to be confirmed.

Hope this helps.

Daniel

Advertisements

VMM 2012 SP1 – Error 26874 when applying logical switch to host (or during bare metal build)

Error (26874)
This operation is not permitted since uplink port profile set (Uplink_Port_Profile) in physical adapter on host would go out of scope for host

Recommended Action
Delete the logical switch instance on the affected host(s) and retry the operation

—————————————————————————————————————–

This error will occur when you are trying to assign a logical switch to a host that is in the wrong host group.

The host group must be associated with the logical switch you are trying to apply to the host.